XY Stages

ALD-115-E1P

1
XY stage
Estimate separately
Direction of travel XY axis two directions
Travel +/-75 mm
Table size 125 mm x 125 mm
YESRoHS対応状況

Product documentation

Description

Motorized stage by using ball bushing for moving guide.
It is used for various sensors and automatic positioning of workpieces.
Pre-HOME sensor and LIMIT sensor position can be adjusted.

Specifications

Direction of travel XY axis two directions
Travel +/-75 mm
Table size 125 mm x 125 mm
Motor Equivalent to PK543NBW (5-wire type pentagonal connection 0.75A /phase)
Resolution 0.002 mm
Feed screw Ball screw
Feed screw lead 1 mm
Guiding method Ball bushing
Travel accuracy HV Straightness (horizontal and vertical) 0.08 mm
Positioning accuracy 0.10 mm (no load), 0.60 mm (4kg on load)
Repeatability +/-0.015 mm
Lost motion 0.03 mm
XY Perpendicularity 0.06 mm
Moment rigidity -
Load capacity 98 N (10 kgf)
Weight 11 kg
Maximum speed 16 mm/s (at 8,000 pps)
Material / Surface treatment Aluminum alloy/White alumite
HOME sensor Normally open contact (make contact, A contact) operation, Photo sensor
*non-adjustable
Pre-HOME sensor Normally closed contact (break contact, B contact) operation, Photo sensor
*adjustable range : +/-75mm
LIMIT sensor Normally closed contact (break contact, B contact) operation, Photo sensor
*adjustable range : 0 to +/-75mm
Compatible cable 0.75-A type (ACB-STD2, ACB-STD3, ACB-STD-D3, ARC-STD2, ARC-STD-D2, ARC-STD3 or ARC-STD-D3, be sold separately)
Standard accessories Inspection certificate
Mounting screw : M4 Hexagon socket head cap screws (4 pcs)
Supplemental note *Dedicated parameter setting for QT-A (Parameter No.4): 14

Connection method- Cable, Controller and Driver -

Operating principle of the Sensor and Timing Chart

Motor specifications