Goniometer Stages

ATS-1230-HP

1
Goniometer stage
Estimate separately
Travel +/-15°
Table size 125 mm x 125 mm
Resolution 0.002°
YESRoHS対応状況

Product documentation

Description

Motorized goniometer stage with a center of rotation in space.
V-groove and cross rollers are used for moving guide.
It is widely used for precision positioning applications such as cameras and sensors.

Specifications

Direction of travel Tilt
Travel +/-15°
Table size 125 mm x 125 mm
Motor Equivalent to PK545NBW (5-wire type pentagonal connection 0.75A/phase)
Resolution 0.002°
Transfer mechanism Worm gear mechanism
Guiding method V-groove and Cross roller
Positioning accuracy 0.025°
Repeatability +/-0.002°
Stage height 48 mm
Center of rotation 112 mm
Positioning accuracy of rotatation center φ0.05 mm
Lost motion 0.002°
Moment rigidity 0.08sec/N*cm (Yaw), 0.03sec/N*cm (roll)
Load capacity 98 N (10 kgf)
Weight 2.7 kg
Maximum speed 10°/s
Material / Surface treatment Aluminum alloy / White Alumite
HOME sensor Normally open contact (make contact, A contact) operation, Photo sensor
*non-adjustable
Pre-HOME sensor Normally closed contact (Break contact, B contact) operation, Photo sensor
*adjustable range : +/-15°
LIMIT sensor Normally closed contact (Break contact, B contact) operation, Photo sensor
*adjustable range : +/-15°
Compatible cable 0.75-A type (ACB-STD2, ACB-STD3, ACB-STD-D3, ARC-STD2, ARC-STD-D2, ARC-STD3 or ARC-STD-D3, be sold separately)
Standard accessories Inspection certificate
Mounting screw : M4 Hexagon socket head cap screws (4 pcs)
Supplemental note *Dedicated parameter setting for QT-A (Parameter No.4): 14

Connection method- Cable, Controller and Driver -

Operating principle of the Sensor and Timing Chart

Motor specifications